What was found
AFT CARGO COMPT BETWEEN FR64 TO FR65 STGR 44 VERTICAL FLOOR SUPPORT CORRODED. SSI 534107. BLENDED FLOOR SUPPORT DAMAGE DIM L=1.5" X W=.8" X D=.015 OUT OF LIMITS. REMOVED AND REPLACED NEW PROFILE FORCE SUPPORT IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPT BETWEEN FR64 TO FR65 STGR 44 VERTICAL FLOOR SUPPORT CORRODED. SSI 534107. BLENDED FLOOR SUPPORT DAMAGE DIM L=1.5" X W=.8" X D=.015 OUT OF LIMITS. REMOVED AND REPLACED NEW PROFILE FORCE SUPPORT IAW A319 SRM 51-42-11.