What was found
FWD PIT LT FRAME REPAIR MISSING FASTENER, DENT UNDERNEATH NOT ADDRESSED BS 580, STR 26L- STR 27L FAA FINDING DURING AAI INSPECTION. REMOVED REPAIR ANGLE IAW SRM 51-40-02. CUT OUT DENT DAMAGE TO FRAME IAW SRM 53-00-07, REPAIR 5. HFEC INSPECTION PERFORMED IAW NDT MANUAL PART 6 51-00-19. .040 INSURANCE CUT/BLEND IAW SRM 53-00-07 STEP 2. ALODINED, PRIMED AND TOP-COATED ALL PARTS AND CUTOUT OF FRAME DENT IAW SRM 51-20-01. RE-INSTALLED FRAME REPAIR IAW SRM 51-40-02 AND SRM 53-00-07 REPAIR 5.