What was found
MAIN CABIN, FLOORBEAM AT BS 1675 BL 0 SEVERE CORROSION. REMOVED FLOORBEAM IAW SRM 51-40-02- NEW FLOORBEAM LOCATED, DRILLED AND DEBURRED IAW B757 SRM 51-40-02- NEW FLOORBEAM INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN, FLOORBEAM AT BS 1675 BL 0 SEVERE CORROSION. REMOVED FLOORBEAM IAW SRM 51-40-02- NEW FLOORBEAM LOCATED, DRILLED AND DEBURRED IAW B757 SRM 51-40-02- NEW FLOORBEAM INSTALLED IAW SRM 51-40-02.