What was found
DURING CHECK, FOUND FWD PIT SLOPE PANEL 132JF IS MISSING UPPER SKIN AROUND TIE DOWN FITTINGS. FABRICATED NEW ON STAM TRAVELER T12/927775 IAW DWG 3D25-37705. DAMAGE DIM: L=9.5 W=8.5 AND INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK, FOUND FWD PIT SLOPE PANEL 132JF IS MISSING UPPER SKIN AROUND TIE DOWN FITTINGS. FABRICATED NEW ON STAM TRAVELER T12/927775 IAW DWG 3D25-37705. DAMAGE DIM: L=9.5 W=8.5 AND INSTALLED.