What was found
UTILITY AREA FLOORBEAM AT FR 66 TO FR 68 LT Y1292 UPPER SURFACE SEVERAL HOLES CORRODED. REMOVED FLOORBEAM +Y1292 FR66 TO 68 IAW A320 SRM 51-42-11. RECEIVED NEW FLOORBEAM INSTALLED NEW FLOORBEAM IAW A320 SRM 51-42-11. BLENDED OUT CORROSION IAW A320 SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-31-15 FIG 101. RETAIN FOR RECORD.