What was found
EMERGENCY FLOOR LIGHTING DAMAGED LEFT SIDE ROW 11-20/35-46. RIGHT SIDE ROW 1-11/25-34. RT FWD COAT CLOSET RED LIGHT INOP. WIRE BEHIND SEAT 5A NEEDS SPLICE INSTALLED. WIRE WAS CUT. REPAIRED WIRING BEHIND SEAT 5A. FOUND WIRES SHORTED AT SEAT 17AB. REPAIRED SAME. RE-INSTALLED ORIG POWER SUPPLY M9008. REPLACED FUSES F1 AND F3 ON POWER SUPPLIES M9008 AND M9009 ALL PER B767 WSPM CH 20. ALL EMERGENCY LIGHTS NOW OPS NORMAL.