Service difficulty report · Floor Support · Airbus A319114

Difficulty date
April 20, 2012
Submitted
April 24, 2012
Operation
Air carrier
Aircraft
N321NB
Make and model
Airbus A319114
Aircraft serial
1414
Aircraft time
5,204 hours, 2,937 cycles
Part
Floor Support
Part number
D5311281400200
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FORWARD UTILITY FLOOR SUPPORT AT FR 20 -Y1292 HAS 1 IN WIDE X 1.5 LONG AREA OF EXFOLIATION. RETAIN FOR RECORDS. BLENDED AREA IAW A319 SRM 51-74-00 AREA DIMENSIONS AFTER REWORK L=1.5"W=1.4"D=.048" ORIG MAT THICKNESS .079 FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-11-14 FIG 105. REMOVED AVIONICS BRACKET FWD AND AFT. RMVD FLOOR SUPPORT AND 1 EA SPLICE IAW A319 SRM 51-42-11. RECEIVED NEW FLOOR SUPPORT. TRANSFERRED 7 EACH BRACKETS IAW A319 SRM 51-42-11. LOCATED AND DRILLED NEW FLOOR SUPPORT IAW A319 SRM 51-42-11. INSTALLED, ALNG W/ BRACKETS.

More about the Airbus A319-114