What was found
DURING INSPECTION, FOUND WEB DAMAGED AT CUSP ANGLE, LOWER SIDE BS 1635, LBL 65. MAINTENANCE REMOVED THE CUSP WEB, POSITIONED, LOCATED, AND SIZED ALL HOLES IAW DWG 146N8722, INSTALLED OTBD ROW OF FASTENERS AND REPLACED THE CUSP WEB IAW DWG 146N8722.