What was found
FWD CABIN FLOOR STRUCTURE CORROSION ON SEAT TRACK, STA 145.5 TO STA 255, LBL 44. REPLACED SEAT TRACK SECTION TO FACTORY SPLICE STA 196 TO STA 304 PER MD88 SRM 53-05 AND MD88 DWG 5930547.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN FLOOR STRUCTURE CORROSION ON SEAT TRACK, STA 145.5 TO STA 255, LBL 44. REPLACED SEAT TRACK SECTION TO FACTORY SPLICE STA 196 TO STA 304 PER MD88 SRM 53-05 AND MD88 DWG 5930547.