What was found
AVIONICS DOOR SUPPORT FR 21 HAS CORROSION. REMOVED DAMAGED DOOR SUPPORT AT FR 21 IAW SRM A319 51-42-11. FABRICATED NEW SUPPORT IAW SRM 53-11-14. TREATED AND PRIMED APPLIED PAINT IAW SRM 51-21-11 AND 51-75-12. LOCATED AND DRILLED INSTALLED NEW SUPPORT IAW SRM 51-44-11 AND 51-42-11. APPLIED TOPCOAT TO FASTENERS AND APPLIED CIC IAW SRM 51-75-12 AND DELTAPROCESS STANDARD 900-2 NR 4. BLENDED AREA IAW SRM 51-74-00, L=1.0" W=1.0" D=.030". FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14.