As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION CRACK FOUND AT THE FLOOR SUPPORT WEB UPPER CHORD AT BS 500 TO 520 LBL 67.0 ON FLOOR SUPPORT WEB AREA, REMOVED AS PER SRM 51-40-02. NEW UPPER CHORD ANGLE FABRICATED AS PER DWG 69B19165. NEW UPPER CHORD INSTALLED AS PER SRM 51-40-02.