What was found
FWD CARGO COMPT BILGE AREA STA 446 BETWEEN L29L-L30 WITH CORROSION. REMOVED CORROSION FOUND OUT OF LIMITS IN REF SRM 53-00-01. CUT FRAME SECTION STA 446 BETWEEN L26L AND L26R IN REF SRM 53-10-02 VOL II. LOCATED AND DRILLED NEW SECTION OF FRAME IN REF SRM 51-10-05. FABRICATED SPLICES IN REF SRM 53-10-01 VOL I. TREATED AND PRIMED FRAME AND SPLICE IN REF MD90 SRM 51-10-3 VOL II. INSTALLED FRAME AND SPLICE AT STA 446 BETWEEN L26L AND L26R IN REF SRM 51-30-02 AND 51-30-05 VOL I AND 51-10-02 FIG 2.