What was found
DURING INSPECTION, FOUND CRACK INDICATION ON BS 1265 FRAME AT STRINGER 26R. MAINTENANCE REPAIRED AREA PER PRI 502611-14AD REV 0 AND REV 1. COMPARED TO ER/A 502611-14AD REV.0 FOUND COMPLIANT.