What was found
LIGHTNING STRIKE DAMAGE AT BS 889, S24R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LIGHTNING STRIKE DAMAGE AT BS 889, S24R. DRILLED OUT DAMAGED RIVET 10X MAG VISUAL INSPECTION, NO CRACKS. INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201 SECT II.