As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND AT FORE & AFT SUPPORTS FOR LOWER CENTER LAVATORY PANEL. AFT SUPPORT REMOVED ON NR 262 LOCATED ALL FASTENER HOLES AND SIZED DWG 149N7701. INSTALLED AFT SUPPORT BRACKETS FOR BOTH LEFT AND RIGHT PANEL SUPPORT BRACKETS DRILLED HOLES FOR NUTPLATES PAINTED HOLES AND INSTALLED NUTPLATES.