What was found
CORROSION FOUND AT AFT CARGO DOOR CUTOUT UPPER BEAM AT BS 1212 L19R. REMOVED AND REPLACED BEAM PER SRM 51-30-05 VOL II.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND AT AFT CARGO DOOR CUTOUT UPPER BEAM AT BS 1212 L19R. REMOVED AND REPLACED BEAM PER SRM 51-30-05 VOL II.