What was found
AT PSV CHECK, SRM 53-24-0D, PERMANENT REPAIR AFT BAG BIN AFT OF DOOR HAS HOLE IN FLOOR PANEL. C/W SRM 53-24-0D, PERMANENT REPAIR AFT BAG BIN AFT OF DOOR HAS HOLE IN FLOOR PANEL. COMPLETED ON N/R 14. REMOVED PATCH, CLEANED AREA AND FABRICATED NEW DOUBLER OUT OF 2024 T3 .063 ORIGINAL MATERIAL2024 T3 .050 PER SRM 53-01, FIG 4 SHEET.