What was found
FWD CARGO DOOR CUTOUT FLOOR WEB HAS CORROSION AROUND FASTENER HOLES. REPLACED FLOOR WEB IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO DOOR CUTOUT FLOOR WEB HAS CORROSION AROUND FASTENER HOLES. REPLACED FLOOR WEB IAW SRM 51-40-02.