What was found
DURING INSPECTION, FOUND PASSENGER SEAT 13D EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. MX REPLACED EMERGENCY LIGHT HOUSING IAW CMM 25-27-79. SEAT 13D EMERGENCY LIGHT OPS, NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND PASSENGER SEAT 13D EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. MX REPLACED EMERGENCY LIGHT HOUSING IAW CMM 25-27-79. SEAT 13D EMERGENCY LIGHT OPS, NORMAL.