What was found
FOUND DENT BETWEEN STRINGER 18 & 19L 4 FT FWD OF L2 DOOR. MEASURED DEPTH 0.105. INSPECTED DENT IAW SRM 53-00-01 FOUND TO BE WITHIN LIMITS OF FIGURE 101, NOTE A AND DETAIL 111. FAILED NOTE J OF SRM 53-00-01 WAVINESS LIMIT SHOWN IN SRM 51-10-01, FIG 3.