What was found
DURING OPEN HOLE HFEC INSPECTION ON LT SIDE, BS 1160 TENSION TIE FOUND ONE CRACK AT FWD CHANNEL, LWR ROW 10TH FASTENER HOLE FROM OTBD AS MARKED. REPAIR, REAMED OVERSIZE IAW SB747-53A2507, REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OPEN HOLE HFEC INSPECTION ON LT SIDE, BS 1160 TENSION TIE FOUND ONE CRACK AT FWD CHANNEL, LWR ROW 10TH FASTENER HOLE FROM OTBD AS MARKED. REPAIR, REAMED OVERSIZE IAW SB747-53A2507, REV 1.