What was found
CORROSION ON UPPER SURFACE OF FLOORBEAM AT BS 1640 BL 0 TO LBL 15. REMOVED CORROSION IAW SRM 53-00-51, PG 104, FIG 101, DETAIL 4. FOUND OUT OF LIMITS IAW SRM 53-00-51, PG 104, FIG 101, DETAIL 4. CUT OUT UPPER SURFACE FLOORBEAM IAW SRM 53-00-51, REPAIR 3, PG 201, DETAIL 1. LOCATED AND DRILLED FLOORBEAM UPPER TEE ANGLES AND STRAPS IAW SRM 51-40-05, PG 1-4. TREATED IAW SRM 51-20-01, PG 3-7 AND PG 27. INSTALLED FLOORBEAM UPPER TEE ANGLES, STRAPS IAW SRM 51-40-02, PG 122.