What was found
DURING OPEN HOLE HFEC INSP ON RT SIDE BS 1120 TENSION TIE, FOUND ONE CRACK AT FRAME, UPPER ROW 1ST FASTENER HOLE FROM OTBD. REAMED OVERSIZE FROM 0.216" TO 0.247" DIA SB747-53A2507, REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OPEN HOLE HFEC INSP ON RT SIDE BS 1120 TENSION TIE, FOUND ONE CRACK AT FRAME, UPPER ROW 1ST FASTENER HOLE FROM OTBD. REAMED OVERSIZE FROM 0.216" TO 0.247" DIA SB747-53A2507, REV 1.