What was found
DURING INSPECTION, FOUND FORWARD CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR16 TO FR21, Y1292 UPPER FLANGE HAS CORROSION. BLENDED CORROSION ON Y1292 FLOOR SUPPORT IAW SRM 51-74-00 DIM ON CROWN AT SEAT TRACK IS L=2.0 W=.375 D=.053 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15, FIG 102. REPLACED FWD CABIN FLOOR SUPPORT IAW SRM 51-42-11.