What was found
DURING OPEN HOLE HFEC INSPECTION ON LT SIDE BS 1180 TENSION TIE FOUND ONE CRACK AT WEB, UPPER ROW 1ST FASTENER HOLE FROM OTBD. REAMED FROM 0.278" TO 0.309" DIA IAW REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OPEN HOLE HFEC INSPECTION ON LT SIDE BS 1180 TENSION TIE FOUND ONE CRACK AT WEB, UPPER ROW 1ST FASTENER HOLE FROM OTBD. REAMED FROM 0.278" TO 0.309" DIA IAW REV 1.