What was found
DURING OPEN HOLE HFEC INSPECTION ON RT SIDE BS 1160 TENSION TIE FOUND ONE CRACK AT FWD CHANNEL, UPPER ROW 3RD FASTENER HOLE FROM OTBD. REAMED OVERSIZE FROM 0.187" TO 0.199" DIA IAW SB747-53A2507, REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OPEN HOLE HFEC INSPECTION ON RT SIDE BS 1160 TENSION TIE FOUND ONE CRACK AT FWD CHANNEL, UPPER ROW 3RD FASTENER HOLE FROM OTBD. REAMED OVERSIZE FROM 0.187" TO 0.199" DIA IAW SB747-53A2507, REV 1.