What was found
DURING OPEN HOLE HFEC INSPECTION ON RT SIDE BS 1220 TENSION TIE, FOUND ONE CRACK AT STEEL PLATE, UPPER ROW 5TH FASTENER HOLE FROM OTBD. STEEL PLATE REMOVED IAW SRM 51-40-02 AND FABRICATED IAW DWG 65B09631, REV AG AND INSTALLED SRM 51-40-02.