What was found
PERFORMED OPEN HOLE HFEC INSPECTION ON NR 3 RT MAIN ENTRY DOORWAY UPPER AFT CORNER FASTENER HOLES, FOUND ONE CRACK ON BEARSTRAP AT 2ND HOLE OF 2ND ROW FROM BELOW DOUBLER AREA CLASSIFIED AS 'LARGE'. REPAIRED IAW PRI 509724-14AD REV 0,1,3,5 DATED 09 JAN 20 13 19:14. PRI 509724-14AD, REV 0,1,3,5 COMPARED WITH ERA 509724-14, REV O FOUND IN COMPLIANCE.