What was found
DURING OPEN HOLE HFEC INSPECTION AT BS 1265 RT FRAME INNER CHORD AND WEB FOUND CRACK INDICATION AT THE FASTENER HOLE 4TH LAYE R 9 O'CLOCK DIRECTION VIEW FROM AFT. BS 1265 RT FRAME INNER CHORD AND WEB FOUND CRACK AT 4TH LAYER 9 O`CLOCK DIRECTION REPAIRED IAW PRI 509705-14AD, REV 0,1,2,3 DATED 14 JAN 2013 20:04. PRI 509705-14 AD, REV 0, 1, 2, 3 COMPARED WITH ERA 509705-14AD, REV 0 FOUND IN COMPLIANCE.