What was found
PERFORMED OPEN HOLE HFEC ON NR 3 LT MAIN ENTRY DOORWAY UPPER AFT CORNER, FOUND ONE CRACK ON SKIN 9TH HOLE OF 1ST ROW FROM BELOW DOUBLER AREA CLASSIFIED AS "MEDIUM". NR 3 LT MAIN ENTRY DOORWAY UPPER AFT CORNER ONE CRACK ON SKIN 9TH HOLE OF 1ST ROW FROM BELOW DOUBLER AREA REPAIRED IAW PRI 509 723-14AD, REV 0,1,2,3.