What was found
PERFORMED OPEN HOLE HFEC ON NR 3 LT MAIN ENTRY DOORWAY, UPPER AFT CORNER, FASTENER HOLES FOUND ONE CRACK ON SKIN 17TH HOLE OF 1ST ROW FROM BELOW DOUBLER AREA CLASSIFIED AS "MEDIUM" AS MARKED. NR 3 LT MAIN ENTRY DOORWAY UPPER AFT CORNER FASTENER HOLES 01EA CRACK ON SKIN 17TH HOLE OF 1ST ROW FROM BELOW DOUBLER AREA REPAIRED IAW PRI 509723-14 REV 0,1,3,5 DATED 11 JAN 2013 21:37. PRI 509723-14 REV 0,1,3,5 COMPARED WITH ERA 509723-14AD REV O, FOUND IN COMPLIANCE.