What was found
DURING HMV, CORROSION WAS FOUND ON THE RT WING CENTER SECTION UPPER WING SKIN AT STA 954 AND BL 0. SUBSEQUENTLY, THE CORROSION WAS R & R IAW ER/A 504829-14. ACCOMPLISHED SECTION 1 OF REPAIR IAW ER/A 504829-14, REV O. REMOVED CORROSION FROM CENTER TANK, RBL 58, BS 955 IAW SRM 51-10-03, PARA 26 VOL II UT AREA AND FOUND TO BE OUT OF LIMITS IAW NDT SPM, PART 4 04-00-07, & SRM 53-00-01, FIG 3, VOL I. ORIG .235 AND LOWEST DEPTH IS .112 HFEC AREA IAW NDTSPM PART 6, 06-10-01 AND FOUND NO ADDITIONAL DEFECT OR CRACKS. FABRICATED REPAIR PARTS AND INSTALLED REPAIR PARTS IAW ER/A 504829-14, REV 14, SEC 1 CAPPED SEAL ALL TANK FASTENERS IAW SRM 51-20-00, PARA 9, VOL II.