What was found
DURING INSPECTION, FOUND CORROSION ON STRINGER 42L AMD BETWEEN FR 56 TO FR 57 OF AFT CARGO COMP. L=9.032", W=0.811", D=0.002" APPROX. PERFORMED PERMANENT REPAIR ON STRINGER 42L AND BETWEEN FR 56 TO FR 57 OF AFT CARGO COMPARTMENT IAW SRM 53-00-15 PARA 4A, TABLE 201, FIG 201, FIRST INSPECTION AFTER REPAIR EMBODIMENT REQUIRED AT 60000 FC AND 75000 FH IAW SRI 53-00-13-2-001-00, TABLE 201 PARA 3A AND TABLE 205.