What was found
DURING INSPECTION, FOUND AFT UTILITY FLOOR SUPPORT -Y765 BETWEEN FR66 AND FR70 HAS SIX AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT UTILITY FLOOR SUPPORT -Y765 BETWEEN FR66 AND FR70 HAS SIX AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.