DURING INSPECTION, FOUND COCKPIT AREA AT FR11+Y765, FLOOR SUPPORT WEB CRACKED. CHECK LIMITS ON CRACK AND LENGTH .815" IS OUT OF LIMITS. REMOVED FLOOR WEB SUPPORT, LOCATED, DRILLED AND INSTALLED NEW SUPPORT WEB AT FR1 1 +Y765 IAW SRM 53-11-14, 51-42-11 AND 51-44-11 AT FR11 +Y76 5.