As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION, FOUND FWD CARGO AT FR 31 BETWEEN CENTERLINE AND STR 43R, SHEAR TIE HAS CORROSION. CHECKED LIMITS L=1.00" W=1.00" D=0.010" NO ALLOWABLE DAMAGE IAW SRM 53-21-12. INSTALLED FABRICATED SHEAR TIE ON STAM TRAVELER T13/982826 MAT 2024-0 .063C BATCH 1942022 HEAT TREATED TO T4 IAW AMS 27705 IAW SRM 53-21-12 AND SRM 51-42-11.