What was found
RT WING NR 6 SLAT T/E WEDGE FOUND DELAMINATION 1.5" FROM T/E, APPROX .7500 DIAMETER AND .5" INBD OF EXISTING DOUBLER REPAIR. RT WING NR 6 SLAT T/E WEDGE BONDED REPAIR DOUBLER IAW SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING NR 6 SLAT T/E WEDGE FOUND DELAMINATION 1.5" FROM T/E, APPROX .7500 DIAMETER AND .5" INBD OF EXISTING DOUBLER REPAIR. RT WING NR 6 SLAT T/E WEDGE BONDED REPAIR DOUBLER IAW SRM 51-70-10.