As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 66 TO FR69 Y-765 UPPER FLANGE CORRODED. REMOVED CORROSION IAW SRM 51-74-00. BLENDED AREA MEASURES L=4.0" W=1.0" D=.025" FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, ORIG MAT .157". R & R FLOOR SUPPORT Y-765 BTW FR66 - FR70 IAW SRM 51-42-11 & DWG D53472000.