What was found
DURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 68-69 Y-1292 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. AREA MEASURES L:4" W:3" D:.108" ORIG MAT. .155". FOUND OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACED FLOOR SUPPORT Y-1292 FROM FR 68-69 IAW SRM 51-42-11.