What was found
DURING INSPECTION, FOUND AFT UTILITY AREA FLOOR SUPPORT BETWEEN FR 64 TO FR 66 Y-1292 HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. AREA MEASURES L:1" W:1" D:.075" ORIG MAT. .100". FOUND OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R FLOOR SUPPORT Y-1292 FROM FR 64-66 IAW SRM 51-42-11.