What was found
DURING INSPECTION, FOUND FORWARD CABIN FLOOR SUPPORT BETWEEN FR18-20 Y-254, UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. CHECKED LIMITS L=3.40" W=0.03" D=0.057 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 FIG 105. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 TRM 53-21-01 & DWG NR D53110422.