What was found
DURING INSPECTION, FOUND AFT CABIN FLOOR SUPPORT LT SIDE BTW FR 65 TO FR 66, Y1732 UPPER SURFACE FLANGES & AROUND HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 L=1.73" W=1.20" D=.043NO ALLOWABLE LIMITS FOR THIS AREA. REPLACED FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 10 D53474250, PN D5347207500000.