What was found
MID CARGO COMPARTMENT DOOR FRAME BEAM CORRODED AROUND FASTENER HOLE, 5" FORWARD OF STA 750. BLENDED, ALODINED, FABRICATED, ANNEALED, PRIMED, AND INSTALLED NEW REPAIR DOUBLER AND FILLER IAW SRM 53-60-02, FIG 9, SHEETS 3 & 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID CARGO COMPARTMENT DOOR FRAME BEAM CORRODED AROUND FASTENER HOLE, 5" FORWARD OF STA 750. BLENDED, ALODINED, FABRICATED, ANNEALED, PRIMED, AND INSTALLED NEW REPAIR DOUBLER AND FILLER IAW SRM 53-60-02, FIG 9, SHEETS 3 & 4.