What was found
RT WING T/E, LOWER INBD FIXED PANEL, AFT STIFFENER IS DEEPLY CHAFED. REMOVED CORROSION ON WING T/E. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 57-00-01, FIG 3. CUTOUT DAMAGED AREA. FABRICATED, DRILLED INSTALLED DOUBLER AND FILLER IAW 51-70-01 FIG 1, 51-10-01 FIG 2, 57-20-03 FI 5, 51-30-02, 51-30-01.