What was found
DURING SCHEDULED MX, A CRACK WAS FOUND ON THE FLOORBEAM AT BS 522. CRACKED FLOORBEAM WAS REPAIRED AND CORROSION WAS REMOVED AND FOUND TO BE WITHIN ACCEPTABLE LIMITS. REPAIR ACCOMPLISHED IAW SRM 51-10-3 AND ER/A 511165-14MA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED MX, A CRACK WAS FOUND ON THE FLOORBEAM AT BS 522. CRACKED FLOORBEAM WAS REPAIRED AND CORROSION WAS REMOVED AND FOUND TO BE WITHIN ACCEPTABLE LIMITS. REPAIR ACCOMPLISHED IAW SRM 51-10-3 AND ER/A 511165-14MA.