What was found
DURING INSPECTION, FOUND CORROSION ON BEAM -Y765 LOCATED FR 65+21" AFT CABIN FLOOR STRUCTURE L=0.5" W=0.025" D=0.001" APROX SSI 534147. REPLACED BEAM -Y765 LOCATED FR 65+21" AFT CABIN FLOOR STRUCTURE IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON BEAM -Y765 LOCATED FR 65+21" AFT CABIN FLOOR STRUCTURE L=0.5" W=0.025" D=0.001" APROX SSI 534147. REPLACED BEAM -Y765 LOCATED FR 65+21" AFT CABIN FLOOR STRUCTURE IAW SRM 51-72-11.