What was found
DURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1732 LOCATED FR.65+19.5" RT SIDE AFT CABIN FLOOR STRUCTURE L=1" W=0.5" D=0.002" APROX. REPLACED FLOORBEAM -Y1732 LOCATED FR 65 TO FR 66 RT SIDE CABIN FLOOR STRUCTURE IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1732 LOCATED FR.65+19.5" RT SIDE AFT CABIN FLOOR STRUCTURE L=1" W=0.5" D=0.002" APROX. REPLACED FLOORBEAM -Y1732 LOCATED FR 65 TO FR 66 RT SIDE CABIN FLOOR STRUCTURE IAW SRM 51-72-11.