What was found
DURING INSPECTION, FOUND CORROSION ON CENTER FITTING FWD PAX CABIN BETWEEN FR 16+5" TO FR 19+5" AND AT LEVEL OF STR 23R. L=0.230", W=0.113", D=0.002". REPLACED CENTER FITTING IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON CENTER FITTING FWD PAX CABIN BETWEEN FR 16+5" TO FR 19+5" AND AT LEVEL OF STR 23R. L=0.230", W=0.113", D=0.002". REPLACED CENTER FITTING IAW SRM 51-72-11.