What was found
DURING INSPECTION, FOUND AFT CABIN UTILITY ARE FLOOR SUPPORT BETWEEN FR 64-66,Y765 UPPER SURFACE FLANGE HAS CORROSION. BLENDED AREA L=1.8",W=1.8"D=.034", MAX ALLOWABLE D=.027" AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 AND SRM 51-74-00. REPLACED FLOOR SUPPORT IAW SRM 51-42-11, SRM 51-44-11 AND TRM 53-21-01, RESTORED FINISH IAW SRM 51-75-12.