What was found
MAIN CABIN LT AFT FLOOR SUPPORT FR64 TO FR66 +Y765 HAS CORROSION AROUND FASTENER HOLES. BLENDED AREA IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN LT AFT FLOOR SUPPORT FR64 TO FR66 +Y765 HAS CORROSION AROUND FASTENER HOLES. BLENDED AREA IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53472815.